Centering

Product Reference Guide

3-15

In the example in

Figure 3-1

, the gray area is the full imager field of view

and the white area is the centering window. Bar Code 1 will not be read,
while Bar Code 2 will be.The default centering window is a 128x96 pixel
area in the center of the imager’s field of view. The following diagram
illustrates the default top, bottom, left, and right pixel positions, mea-
sured from the top and the left side of the imager’s field of view, which is
640 by 480 pixels.

If a bar code is not within the predefined window, it will not be decoded
or output by the imager. If centering is turned on by scanning Centering
On
, the imager only reads codes that intersect the centering window you
specify using the Top, Bottom, Left, or Right bar codes.

0

100%

100%

Default

Center

40%

60%

40%

60%

Left

Right

Bottom

Top