Trigger Commands

Product Reference Guide

10-5

This response indicates that the device’s Codabar Coding Enable
(CBRENA) is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.

Trigger Commands

You can activate and deactivate the imager with serial trigger commands.
First, the imager must be put in Manual/Serial Trigger Mode either by
scanning the Manual/Serial Trigger Mode bar code (

page 3-5

), or by

sending the Manual/Serial Menu Command (

page 10-10

). Once the

imager is in serial trigger mode, the trigger is activated and deactivated
by sending the following commands:

Activate:

SYN T CR

Deactivate:

SYN U CR

The imager scans until a bar code has been read, until the deactivate
command is sent, or until the serial time-out has been reached (see

Read

Time-Out on page 3-5

for a description) and the serial command on

page 10-10

).