Linear Symbologies

Product Reference Guide

6-23

UPC-E0 Number System

The numeric system digit of a U.P.C. symbol is normally transmitted at
the beginning of the scanned data, but the unit can be programmed so it
will not transmit it. Default = On.

UPC-E0 Addenda

This selection adds 2 or 5 digits to the end of all scanned UPC-E data.
Default = Off for both 2 Digit and 5 Digit Addenda.

UPC-E1

Most U.P.C. bar codes lead with the 0 number system. For these codes,
use

UPC-E0

(page 6-21). If you need to read codes that lead with the 1

number system, use the UPC-E1 selection. Default = Off.

Off

* On

* 5 Digit Addenda Off

5 Digit Addenda On

* 2 Digit Addenda Off

2 Digit Addenda On

UPC-E1 On

* UPC-E1 Off