The 9145 comes equipped with a minimum of two record ports. Port’s 1 and 2 will always

be record ports
Ports 3 and 4 can be record, monitor, or not equipped.
Ports 5 and 6 will be monitor, or not equipped.
The Ports Installed field and individual Port and Type fields will be preconfigured at the

factory by Teo.
If monitoring is an option, analog stations or outside lines will be attached to the monitor

ports. A Dial-up Monitor Number must be is assigned to the ports. Enter the appropriate

number.
The PIN is a number assigned as a password. After you dial the monitor port number, the

9145 provides a clicking sound to let you know you can enter the password. In this

example, you dial 123 then # and can listen to the 911 call in progress.
The Monitor Beep Tone and Recording Beep Tone are provided for legal reasons. The beep

tone may be required by law if a call is being monitored or recorded. Check your local and

state law to determine if calls can be observed or recorded.