File alarms – Teo E911 Response System Installation User Manual

Page 64

Advertising
background image

Teo E911 Response Server 9145 Installation Instructions

Page 64

13-280133 Rev. C

F

F

i

i

l

l

e

e

A

A

l

l

a

a

r

r

m

m

s

s

Alarm Text

Alarm Description

Alarm Clearing

Illegal

Executable

9145 detects an invalid or

missing executable

operating system.

Using the Administration PC, connect

and select Publish to Server

→

Firmware Update to clear the alarm.

Illegal

Configuration

File

9145 detects an invalid

configuration.

Using the Administration PC, connect

and select Publish to Server

→

Configuration to clear the alarm.

Configuration

File Missing

9145 detects a missing

configuration.

Using the Administration PC, connect

and select Publish to Server

→

Configuration to clear the alarm.

Illegal Station

Table

9145 detects an invalid

Station Table.

Using the Administration PC, connect

and select Publish to Server

→

Station Data to clear the alarm.

Station Table

Missing

9145 detects a missing

Station Table.

Using the Administration PC, connect

and select Publish to Server

→

Station Data to clear the alarm.

All Flash

Sectors Full

Flash memory is full or the

9145 detects a memory

error.

Perform a system reset and/or power

cycle. If the alarm persists, contact

Teo Technical Support.

Advertising