Quick Set-Up

Verilink QPRI 2921

2-3

Getting Started

After the NCM and QPRI modules and their NIM/CIM have been
installed in their appropriate shelf/slots (self-test has been
successfully completed), connect the Craft Interface Cable
(P/N 458-501788-008) to the Local port on the NCM front panel to
access the ASCII interface.

Terminal

Parameters

Terminal parameters: 19.2 kbit/s baud rate, 8 data bits, no parity,
one stop-bit, and no flow-control. Make sure that the X-On/X-Off
flow control is disabled.

Logging On

1. Press E

NTER

to display the pSH+> prompt and type craft.

2. Press E

NTER

to display the NCM Main Menu.

If the NCM Main Menu display

Figure 2-2

shows the QPRI in the

proper shelf/slot position, you may continue with the
configuration tasks.

The default password for the NCM will give the user Access Level 2
permissions. If you need a higher access level, see your NCM 2000
User Manual
for more information.

Bus

Compatibility

If there is no indication of the QPRI on the “shelf map” on the NCM
Main Menu, the modules may be assigned to different busses on
the shelf backplane.

NCMs are usually sent out with their default bus being the C bus.
Other modules usually are sent out with their default bus being the
A bus.

Assign the QPRI to the bus on which the NCM resides by accessing
the QPRI’s ASCII port directly.

1. Connect the Craft Interface Cable directly to the LOCAL port

on the QPRI module.

2. Press E

NTER

.

3. From the QPRI Main Menu, select the following:

O) node administration>B) change the ACP bus

4. Once the bus assignment has been made, reboot the

reassigned module by either

Using the

reset

reset

reset

reset command from the Controller Administration

Menu, option R, or

Reseating the module in its slot.