Dlci statistics screen 4-32 – Verilink WANsuite 5330 (34-00302.F) Product Manual User Manual

Page 110

Advertising
background image

4-32

W A N s u i t e 5 3 3 0

Receiving FECN/

BECN

When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.

Values: Yes, No
Default: No

CIR Threshold

Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.

CIR Alarm

Reports if the Tx over CIR threshold has been exceeded.

Bits Over Be Threshold

Sets the Tx over Be alarm threshold. This threshold is the number of bits per
second in excess of CIR + Be during a 15-minute interval. Setting this field to
“0” (zero) disables the alarm.

Bits Over Be Alarm

Reports if the Tx over Be threshold has been exceeded.

Congestion Threshold

Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.

Congestion Alarm

Reports if the Rx Congestion threshold has been exceeded.

BECN within CIR

Alarm

Reports if Backward Explicit Congestion Notification (BECN) has been
received within CIR.

UAS Threshold

Sets the Unavailable Seconds (UAS) alarm threshold. This threshold is the
number of seconds after which the DLCI is unavailable. Setting this field to
“0” (zero) disables the alarm.

UAS Alarm

Reports if the UAS threshold has been exceeded.

DLCI Statistics Screen

The DLCI Details screen provides a “DLCI Statistics” prompt that displays a
table of the statistics for this DLCI as shown in Figure 4.22.