Serial screen, Reset timer 4-8, Serial screen -8 – Verilink WANsuite 5330 (34-00302.F) Product Manual User Manual

Page 86

Advertising
background image

4-8

W A N s u i t e 5 3 3 0

The four columns of the status table are as follows:

The table provides error status and alarm threshold information for the
following error parameters:

LOS

Sets the Loss of Signal seconds threshold. A LOS is a 1-second period in
which the DDS received signal is interrupted. The default value is None.

OOF

Sets the Out of Frame seconds threshold. An OOF is a 1-second period in
which a frame sync loss occurred. The default value is None.

OOS

Sets the Out of Service seconds threshold. An OOS is a 1-second period
during which the Out of Service code is received. The default is None.

BPV

Sets the Bipolar Violation Errored seconds threshold. A BPV is a 1-second
period in which at least one bipolar violation occurred. The default is None.

Reset Timer

The status table also provides a means for establishing the Reset Timer
threshold. This read/write field is used to establish the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset. The default value is 30.

The Network screen also provides a “Clear Alarms” prompt, which resets the
alarm conditions and counts to zero.

Serial Screen

The Serial screen (Figure 4.8) lets you view and make changes to the unit’s
Serial interface configuration as described in the paragraphs below. To make
changes to any Serial parameter, simply set the parameter to the desired
selection and press the “Esc” key.

Status

Displays the current status of the network port.

Alarm

Displays the alarm value of the network port. The unit
declares an alarm as soon as the count exceeds the established
threshold.

Count

Displays the number of events or occurrences of this
condition that have been detected.

Threshold

This forced-choice field can be set to a desired threshold for a
specific error condition. Available threshold choices are
None, 1, 2, 3, 4, 5, 10, 20, and 30.