Current pin status, Ethernet (ip details) screen, Current pin status -11 – Verilink WANsuite 5330 (34-00302.F) Product Manual User Manual

Page 89: Ethernet (ip details) screen -11

Advertising
background image

V T 1 0 0 I n t e r f a c e

4-11

RTS/CTS Delay

The Request To Send/Clear To Send parameter determines how long the unit
waits before it changes the level of CTS to match RTS when the CTS
parameter is set to “Internal.”

Values: Normal (~30 ms delay), Long (~100 ms delay)
Default: Normal

DTR Alarm Control

Lets you set DTR Alarm Control parameters.

Values: Enable, Disable
Default: Disable

DTR Alarm Status

Lets you view the current DTR Alarm status.

Format

Selects the port’s operating mode.

Values: Sync, Async
Default: Sync

Flow Control

Selects the type of flow control to be used if the port is asynchronous.

Values: None, Xon/Xoff, RTS/CTS
Default: None

Character Size

Selects the number of bits to make up one asynchronous character.

Values: Five, Six, Seven, Eight
Default: Eight

Parity

Selects the setting for the parity bit if the port is asynchronous.

Values: None, Odd, Even
Default: None

Stop Bit

Selects the number of bits to end the character.

Values: 1, 2
Default: 1

Current Pin Status

The Current Pin Status, which shows the state of the RS-232 pins, is also
displayed on the Serial screen.

Ethernet (IP Details) Screen

The 10/100 Ethernet (IP Service Details) screen (Figure 4.9) lets you
configure the IP parameters listed below.