W e b S e r v e r I n t e r f a c e

3-33

FrameStart Delay

If this parameter is set to “Enable,” the unit will send FrameStart discovery
and delay frames on this DLCI, and will report the state of the remote
Verilink FSx unit. It will also send SOS frames when the FRAD/router
connected to this unit goes inactive.

Values: Enable, Disable
Default: Enable if Auto Discovery is set to “Yes”; Disable otherwise

FrameStart Status

If the remote unit is a Verilink FSx product and FrameStart Auto Discovery is
enabled, the FrameStart Status field will show the status of the remote unit.
The status is “Active” if both the local and remote DLCIs are active and the
remote unit answers to the discovery frames sent by this unit. The status is
“SOS” if the remote unit is active but the FRAD/Router connected to it is
inactive. The status is “Inactive” in all other cases.

Values: Active, Inactive, SOS
Default: Inactive

Remote DLCI

If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery
is enabled, this displays the DLCI number used on the remote end of this
DLCI.

Values: 16

1023

Default: 0

Remote Unit

If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery
is enabled, this parameter gives the first three digits of the unit ID configured
on the remote end of this DLCI.

Values: 000

999

Default: 000

Round Trip Delay Size

Specifies the frame size (in bytes) of packets making the round trip. If the
Round Trip Delay Size is not configured, the Frame Relay Details values will
be used.

Round Trip Delay Rate

Specifies the rate (in seconds) at which Round Trip Delay packets are sent. If
the Round Trip Delay Rate is not configured, the Frame Relay Details values
will be used.

DLCI Status Table

The bottom portion of the screen shows a table detailing the actual status of and
alarm threshold information for the selected DLCI as follows:

Status

If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”

Values: Active, Inactive
Default: Inactive

Receiving FECN/

BECN

When a frame is received with a congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without a congestion
bit set.

Values: Yes, No
Default: No