Che and bche drying hoppers – AEC HE Mass Flow Series Drying hoppers User Manual

Page 20

Advertising
background image

HE

CHEBCHE Mass Flow Series Drying Hoppers

Page 19

CHE and BCHE Drying Hoppers

In systems where one dehumidifying dryer supplies air to several drying hoppers rigid manifold
lines should be installed for both air delivery and return. The manifold lines should include
butterfly valves leading to each drying hopper to throttle the air flow to the drying hopper
requirements. Air flow can be measured using a pitot tube and an instrument such as a hot wire
anemometer. The measurement should be taken in the line on the downstream side of the
butterfly valve, with all drying hoppers full of material and on line. A by-pass valve is also used
in the air supply line after the last drying hopper, to bleed any excess air flow to the return air
line. Do not bleed this air to atmosphere. Butterfly valves can be installed in the return line to be
able to turn a drying hopper off line. It is very important to have the air supply by-pass valve
installed on the last drying hopper if you choose to turn one drying hopper off line.

Figure 7

Typical Multiple Hopper Drying Hose Installation

Throttle/shutoff valve

Process

return

air
Process

supply

air

Bypass

valve

Advertising