11. Slide the control chassis back into the control housing. The remaining parameters are set

with the keypad.

12. Prepare your unit for startup with a real or simulated load. Restore electrical power.

Figure 11

1/4 DIN Temperature Controller Preset Parameters

Parameter

setting levels

Parameter

description

PV LED

display

TDH SV LED

setting

0

Display at power-up.

Process

temperature

Process

set point

Alarm range.

25

°F

Proportional bandwidth.

39

°F

Reset time.

109 seconds

Rate time.

27 seconds

1

Lower limit value of control range.

0

°F

Upper limit value of control range.

400

°F

Heating control period.

20 seconds

Shift set value.

0

°F

2

Control output variable.

Read only.

Temperature sensor type.

Alarm mode.

Unit number setting w/optional
communications.

Varies with

network.

Baud rate setting w/optional
communications.

Varies with

network.