5 changing the display from fahrenheit to celsius, 6 setting the process air temperature – AEC HE Mass Flow Series Drying hoppers User Manual

Page 30

Advertising
background image

HE

CHEBCHE Mass Flow Series Drying Hoppers

Page 29

5-4 Using the Temperature Controller Anti-Tamper

Lockout Switch

The anti-tamper lockout slide switch prevents unauthorized changes to set points. If the

SW101

switch is

On

, the

Level

,

Down

,

Up

, and

AT

AT

keys are disabled. Only

the process set point and alarm settings may be viewed. Your unit is factory-set with the
protection turned

Off

.

To enable the lockout feature:

1. Disconnect main electrical power to the dryer.

1. Press up the latch at the bottom of the control module’s front panel and slide out the

control chassis.

2. Locate the slide-type switch marked

SW101 {PROTECT}

on the left

circuit board. Slide it to

ON

.

3. Slide the chassis back into the control module housing. Tamper protection will now be

enabled.

5-5 Changing the Display from Fahrenheit to Celsius

To change the display from the factory °F setting to °C:

1. Disconnect main electrical power to the dryer.

1. Press up the latch at the bottom of the control module front panel and slide out the control

chassis.

2. Locate DIP switch

SW201 {FUNCTION}

on the right circuit board.

Slide the #5 pin to

OFF

.

1. Slide the chassis back into the control module housing.

2. Cover the °F label with the °C sticker included in the information packet.

5-6 Setting the Process Air Temperature

To change the process air temperature set point:

„ Press the

Up

button to raise the set point.

„ Press the

Down

Button to lower the set point.

OFF

ON

SW101 {PROTECT}

1

2

3

4

5

6

ON

SW201 {FUNCTION}

ºC

Advertising
This manual is related to the following products: