CHEBCHE Mass Flow Series Drying Hoppers

Page 27

LED Displays and Indicators

PV (Process Value) Display

During normal operation, the large red

PV

LED screen displays the actual process temperature at

the To Process thermocouple. It also lists parameters during setup, and error messages if an error
condition exists.

SV (Set Value) Display

During normal operation, the green

SV

LED screen displays the process set point you selected

for the dryer to maintain. The screen also displays parameter and preset function values during
setup.

OUT

OUT (Output) LED Indicator

The orange

OUT

LED lights when the control output energizes the process air heater.

SHIFT

SHIFT LED Indicator

The orange

SHIFT

LED is not used on WD Dryers.

AT

AT (Auto-Tune) LED Indicator

The orange

AT

LED flashes during the Auto-Tune sequence.

ALM1

ALM1 (Alarm 1) LED Indicator

The red

ALM1

LED lights when the process air temperature has risen more than 25° from the set

point. The alarm relay is energized when this LED lights. All heaters turn off and the blowers
stay on to cool the heaters.

ALM2

ALM2 (Alarm 2) LED Indicator

The red

ALM2

LED is not used.


Controller Buttons

Level Button

Press and hold the

Level button for two (2) seconds or more to select the next of three

indication levels (0, 1, and 2) where specific control parameters may be set. The controller
defaults to Level 0 on power-up.