13. Turn control power on.

The

PV

LED displays four zeros

(0000)

, then displays the current process air

temperature.

14. Press the

MODE

key to page through the Level-0 control parameters. The

PV

LED

displays codes indicating the currently selected mode; the

SV

LED shows the current

setting of the selected parameter. Use the Up and Down arrow keys to select a setting. Set
the Level

0

parameters based on Figure 9 on the previous page.

15. Press the Level key for at least two seconds to access Level

1

parameters. Set them using

the procedure in the previous step.

Note: You can proceed to Level

2

, but these parameters are read-only. Controls with optional

communications have user-set variables (unit address and ID) on Level

2

.

16. Turn off the power switch on the graphic display and remove all electrical power to the

dryer.

17. Press up the latch at the bottom of the control front panel and slide out the control

chassis.

1. Set the #6 position of the DIP-type function selector switch to

OFF

.

It is marked

SW201 {FUNCTION}

and is on the right circuit board.

2. Turn the control power on. The

PV

LED displays four zeros

(0000),

then displays the current process temperature.

3. Auto-tune the dryer using the procedure in Section 5-8 on Page 29.


If the control still fails to control, call the AEC/Whitlock Service Department.

1

2

3

4

5

6

ON

SW201 {FUNCTION}

Advertising
This manual is related to the following products: