HE

CHEBCHE Mass Flow Series Drying Hoppers

Page 41

Level 1 Mode

For adjusting primary control parameters. Execute:

AT

(auto-tuning); set alarm values; set the

control period; set PID parameters.

Level 2 Mode

For adjusting secondary control parameters. Nomad Cart uses E5CK default settings.

Setup Mode

For setting the basic specifications. Set parameters for input type, scaling, output assignments
and direct/reverse operation.

Expansion Mode

For setting expanded functions. Set:

ST

(self-tuning), SP setting limiter. Select: advance PID or

ON/OFF

control.

Option Mode

This mode is only accessible when and option board is installed.

Calibration Mode

For calibrating communication unit E53-CKF. Not used.

A

M

A/M Key

Protect Mode

Limits the use of the menu and

A

M

Automatic/Manual keys. The protect function allows for

setting different levels of security. See

Setting E5CK Security in Protect Mode

on the

following page for E5CK security settings.

Manual Mode

Sets the controller to manual operation mode. Nomad carts are set for manual mode.