Page 44

HE

CHEBCHE Mass Flow Series Drying Hoppers

Figure 16

Default Setting List for 1/16 DIN Process Temperature Controller

Mode

Parameter

Setting range

Default AEC setting

Level 0

SP Set Point

SP Lower Limit to Upper Limit EU

0

Default

Level 0

r - S Run/Stop

Run/Stop

Run

Default

Mode

Parameter

Setting range

Default AEC setting

Level 1

AE AT Execute/Cancel

Off/AT-1/AT-2

Off

Default

Level 1

SP-0 Set Point 0

SP Lower to Upper EU

0

Default

Level 1

SP-1 Set Point 1

SP Lower to Upper EU

0

Default

Level 1

AL-1 Alarm Value 1

-1999 to 9999 EU

0

25.0

Level 1

AL-2 Alarm Value 2

-1999 to 9999 EU

0

25.0

Level 1

AL-3 Alarm Value 3

-1999 to 9999 EU

0

Default

Level 1

P Proportional Band

0.1 to 999.9 %FS

10.0

4.4

Level 1

I Integral Time

0 to 3999 SEC

233

84

Level 1

d Derivative Timer

0 to 3999 SEC

40

13

Level 1 C-SC Cooling Coefficient

0.01 to 99.99

1.00

Default

Level 1

C-db Dead Band

-19.99 to 99.99 %FS

0.00

Default

Level 1 6F-r Manual Reset Value

0.0 to 100.0%

50.0

Default

Level 1

HYS Hysteresis (Heat)

0.01 to 99.99 %FS

0.10

Default

Level 1

CHYS Hysteresis (Cool)

0.01 to 99.99 %FS

0.10

Default

Level 1 CP Control Period (Heat)

1 to 99 SEC

20

Default

Level 1 C-CP Control Period (Cool)

1 to 99 SEC

20

Default

Mode

Parameter

Setting range

Default AEC setting

Level 2

r-L Remote/Local

RMT/LCL

LCL

Default

Level 2 SPrU Sp Ramp Time Unit

M(Minutes)/H(Hour)s

M

Default

Level 2 SPrE Sp Ramp Set Value

0 to 9999 EU

0

Default

Level 2 LbA LBA Detection Time

0 to 9999 SEC

0

Default

Level 2

Au-5 MV at Stop

-5.0 to 105.0 %

0.0

Default

Level 2

Au-E MV at PV Error

-5.0 to 105.0 %

0.0

Default

Level 2

6L-H MV Upper Limit

MV Lower Limit +0.1 to 105.0%

105.0

Default

Level 2

6L-L MV Lower Limit

-5.0 to MV Upper Limit -0.1%

-5.0

Default

Level 2 6rL MV Change Rate Limit

0.0 to 100.0 %/SEC

0.0

Default

Level 2

CnF Input Digital Filter

0 to 9999 SEC

0

Default

Level 2 ALH1 Alarm 1 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 ALH2 Alarm 2 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 ALH3 Alarm 3 Hysteresis

0.01 to 99.99%

0.02

Default

Mode

Parameter

Setting range

Default AEC setting

Level 2 Cn5H Input Shift Upper Limit

-199.9 to 999.9 °C

0.0

Default

Level 2 Cn5L Input Shift Lower Limit

-999.9 to 999.9 °C

0.0

Default