HE

CHEBCHE Mass Flow Series Drying Hoppers

Process Heater Light

CHE and BCHE Models

This green indicator lights when the process air heater is on.

High Process Air Temperature Light

CHE and BCHE Models

This red indicator lights when the temperature at the process air thermocouple is outside the set
alarm value. The alarm mode and value are factory-set to track 25° above the process set point.
Therefore, the alarm value is set as a deviation from the process set point.

When the indicator lights, the alarm relay is energized and all the heaters turn off while the
blowers remain on. When the temperature at the process thermocouple returns to within the
acceptable range, the alarm output is de-energized and the heaters will turn on again
automatically. The alarm range can be altered.

5-2 Using the 1/4 DIN Temperature Controller

Some AEC/Whitlock drying hoppers use a 1/4 DIN microprocessor-based PID temperature
controller for maintaining process air temperature. The controller is a modular, self-contained
unit you can remove from the mounting housing. All parameters except for the process air set
point are factory set and adjusted; normally, no field adjustment to the internal controls is
necessary.

Figure 10

1/4 DIN Controller

AT

ºF

3 0 0

PV

3 0 0

SV

OUT

SHIFT

AT

ALM1

ALM2

Mode key

Down key

Up key

AT (Auto-Tune) key

ALM1 (Alarm 1)
indicator

AT (Auto-Tune)
indicator

ALM2 (Alarm 2)
indicator

SV (Set Value)
display

PV (Process Value)
display

ºF (Fahrenheit) decal

OUT indicator

SHIFT indicator

Level key