AEC HE Mass Flow Series Drying hoppers User Manual

Page 47

Advertising
background image

Page 46

HE

CHEBCHE Mass Flow Series Drying Hoppers

Figure 17

Available Option Boards

Option type

RS232C

RS-485

Event input

Transfer output

Board no.

E53-CK01 E53-CK03 E53-CKB

E53-CKF


Notes:

• Option Mode only visible when an option board is installed.

• Use default settings for Communications board. Contact AEC Whitlock Engineering

for settings on “Event Input” and “Transfer Output” boards.

Mode

Parameter

Setting range

Default

AEC setting

Option

Eu-A Multi-SP Function

0/1

0

Default

Option

Eu-1 Event Input Assign 1

STOP/MAN

STOP

Default

Option

SbCE Communication Stop Bit

½ BITS

2

Default

Option

LEn Comm. Data Length

7/8 BITS

7

Default

Option

PrEY Communication Parity

None/Even/Odd

Even

Default

Option

6PS Comm. Baud Rate

1.2/2.4/4.8/9.6/19.2

9.6 kbps

Default

Option

U-n6 Comm. Unit No.

0 to 99

0

Default

Option

Er-E Transfer Output Type

SP/SP-M/PV/O/C-O

SP

Default

Option

Er-H Xfer Output Upper Limit

5

5

Default

Option

Er-L Xfer Output Lower Limit

5

5

Default

Advertising