AEC HE Mass Flow Series Drying hoppers User Manual

Page 46

Advertising
background image

HE

CHEBCHE Mass Flow Series Drying Hoppers

Page 45

Figure 16

Default Setting List for 1/16 DIN Process Temperature Controller

Mode

Parameter

Setting range

Default AEC setting

Setup

Cn-E Input Type

0 to 21

2

3

Setup Cn-H Scaling Upper Limit

Scaling Lower Limit +1 to 9999 EU

-100

Default

Setup Cn-L Scaling Lower Limit

-1999 to SP Setting Upper Limit -

0.1 EU

0 Default

Setup

dP Decimal Point

0 to 3

0

Default

Setup

d-U °C/F Selection

°C/F

°C

°F

c

Setup CnCE Parameter Initialize

Yes/No

No

Default

Setup

6UE1 Control Output 1

Assignment

Heat/Cool/Alarm 1/ Alarm 2/Alarm

3/LBA

Heat Default

Setup

6UE2 Control Output 2

Assignment

Heat/Cool/Alarm 1/ Alarm 2/Alarm

3/LBA

AL-1 Default

Setup

Sub 1 Auxiliary Output 1

Assignment

Alarm 1/Alm 2/Alm 3/LBA/S.

ERR/E333

AL-2 Default

Setup

ALE1 Alarm 1 Type

0 to 11

2

Default

Setup

AL1n Alarm 1 open in

alarm

NO/NC NO

Default

Setup

ALE2 Alarm 2 Type

0 to 11

2

Default

Setup

AL2n Alarm 2 open in

alarm

NO/NC NO

Default

Setup

ALE3 Alarm 3 Type

0 to 11

2

Default

Setup

AL3n Alarm 3 open in

alarm

NO/NC NO

Default

Setup

6rEu Direct/Reverse

Operation

OR-R/OR-D OR-R

Default

c Check sales order for temperature unit selection.

Mode

Parameter

Setting range

Default AEC setting

Expansion

SL-H Set Point Upper Limit

SP Lower Limit +1 to

Scaling Upper Limit

1300 400.0

Expansion

SL-L Set Point Lower Limit

Scaling Upper Limit to SP

Lower Limit

-200 0

Expansion CnEL

PID/ON/OFF

PID/ON/OFF

PID

Default

Expansion SE ST Adaptive Tuning (Fuzzy)

OFF/ON

OFF

Default

Expansion

SE-b ST Stable Range

0.1 to 999.9 °C/F

15

Default

Expansion

ALFA

α

0.01 to 1.00

0.65

Default

Expansion

AE-G AT Calculated Gain

0.1 to 10.0

1.0

Default

Expansion

rESE Standby Sequence Reset

Setting Method

0/1 0

Default

Expansion

rEE Automatic Return of

Display Mode

0 to 99 SEC

0

Default

Expansion

AE-H AT Hysteresis

0.1 to 9.9 %FS

0.2

Default

Expansion

LbAb LBA Detection Width

0.0 to 999.9 %FS

0.2

Default

Advertising
This manual is related to the following products: