8900NET (Net Card) — Instruction Manual

101

8900NET Software Update From FTP Server

g.

In the File Path field, enter the FTP file path of the software update
file.

The FTP file paths use forward slashes. The directory name “/mod-
ular” is not needed in the path name.

h.

Submit the form and start the update process by entering the user
name and password and clicking on

Apply

.

By default, the Xitami Server has been configured to accept a user
name of “moduser” and a password of “moduser” for the modular
root directory. This may be changed by modifying the ftpusers.sms
file in the C:\Program Files\Xitami directory (see

Password Protec-

tion for Software Upgrades on page 97

).

After you click on

Apply

, the web page will be reloaded, displaying

the Progress Monitor (

Figure 62

).

If an incorrect file name or password is entered, the Progress
Monitor will report the condition and allow you to go back to the
Software download page and re-enter the correct information.

The module software compatibility check uses compatibility infor-
mation included in the Field Update File to ensure that the new soft-
ware was intended for this module. In the event that there is a
mismatch, the Net Board will abort the upgrade.

Note

Do not make any changes to the web page during the software download.

i.

If the file entered in the file path is invalid or the file cannot be
found, a

File Not Found

message will appear in the Progress Monitor

Results line (

Figure 62

). Select the Software Download link or the

Refresh

button to refresh the page to return to the download page

and re-enter the file name.

Figure 62. 8900NET Software Download Progress Monitor