8900NET (Net Card) — Instruction Manual

55

Using the 8900NET GUI

Frame Power Supply Web Pages

Use
this
link

The frame Power Supply 1 or Power Supply 2 status web pages provide:

Power Slot Status – pass/fail status of the supply and fan in the power
supply sled (see

Figure 30

).

A Frame Health Reports link is given to the Frame Health Reporting
web page (

page 42

) where a fault report in the power supply can be

enabled or disabled as an alarm to the Frame Alarm connector on the
rear of the frame.

An LED Reports link is given to the LED Reporting web page (

page 48

)

where the power supply status reporting to the PS1 and/or PS2 LED on
the front of the 8900NET module can be disabled if desired.

When an SNMP manager is installed on the 8900NET module, an
SNMP Trap Reports link will be present. This will link to the SNMP
Reporting web page (

page 48

) where power supply fault and removal

can be configured for reporting to the SNMP manager.

Figure 30. Power Supply Slot Status Page