8900NET (Net Card) — Instruction Manual

Using the 8900NET GUI

Frame Alarm Reporting Web Page

Use
this
link

Selecting the Frame Alarm Reports link on any Frame or 8900NET web
page will bring up the Frame Alarm Reporting web page shown in

Figure 20 on page 43

. This page provides a summary of the various alarms

and warning reports that can be enabled and disabled for the frame com-
ponents for reporting status to the Frame Alarm on the rear of the frame
and the SNMP traps.

Hardware Switch Status

– the Hardware Switch Status section of this web

page displays the current settings of the DIP switches, S1 and S2, on the
8900NET circuit board as described in

8900NET Module Alarm DIP

Switches on page 11

.

Module Health Report status

– under the Hardware Switch Status table is a

message in blue text giving the current status of the Module Health
Report checkbox in the Frame Health Reporting list. When the Module
Health selection is enabled in the Frame Health Reporting table
(

Figure 20 on page 43

), the message will read:

If the Module Health Report checkbox is unchecked in the Frame
Health Reporting list, the message will read:

Note

This message does not reflect the setting made on the Internal Module
Healthbus
control explained later in this section.

Output Format for Warnings

– set the Frame Alarm output on the RS-232

connector to output a pulse or a continuous voltage level when a
warning condition is detected from the Module Health bus. For more
information on the voltage level from the Module Health Bus, refer to

External Frame Alarm on page 28

.

Internal Module Healthbus

– this control is provided to enable or disable

Module Health Bus

FAULT

status reporting to the Frame Status web page

and the Frame Health Reporting table.

When a fault condition is occurring on the Module Health Bus (caused
by 3 or more modules reporting a Warning or Configuration error con-
dition and/or a single module reporting a fault) and the

Internal Module

Healthbus

control is set for

Enable

, the fault will be reported on the Frame

Status web page (

Figure 20 on page 43

) and in the Frame Health

Reporting table (

Figure 22 on page 44

).