Figure 15. 8900NET GUI for Frame Control

During initial polling, modules that do not respond immediately may tran-
sition to a

WARNING, MODULE NOT RESPONDING

status. In this case, this is a tem-

porary status until a maximum number of sequential attempts fail and a
Fault is reported.

Note

The first release of 8960DEC module code causes a Fault condition because
it never responds on the Frame Bus. There is no way for the 8900NET module
to tell the difference between a fully functional early release of 8960DEC and
a module whose Frame Bus Interface has failed.

Note

Early releases of the 8960ENC, 8950DAC, 8950ADC, 8920DAC, 8920ADC,
and the 8916 signal a warning condition due to limited capability over the
Frame Bus. All of these, except the 8916, can be upgraded by the user with
fully capable Frame Bus software.

0612-12

r5

The Links section lists the frame and its current modules. The selected link's Status
page is first displayed and the sub-list of links for the selection is opened. The sub-list
allows you to select a particular information page for the selected device.

Content display section displays the information page
for the selected frame or module (frame slot icons are also
active links).