13. 12 Timeouts
Normally, you will not need to adjust the timeout settings which apply to the
communication with devices. Only change the settings if you fully understand the
consequences.
It may be necessary to adjust channel querying for a Sunny Central Control.
13.12. 1 Settings at the Sunny Central Control
1.
Select "Options/Settings" or click on the "Settings" icon. The "Settings"
window opens.
2.
Select "Timing“.
3.
Choose the following settings for the Sunny Central Control.
•
Archive data acquisition/Channel query: 200 s
•
Archive data acquisition/Storage Time Refresh: 200 s
•
Device detection/First detection: 10 s
•
Device detection/Further detection: 10 s
4.
Click on Save to save the settings.
Restoring Factory Settings
To restore the factory timeout settings, click on <Reset all>.