6  Electrical Connection

Installation Manual

STP10-17TL-IA-en-32

43

6. Follow the same procedure to connect all further

strings.
It is no longer necessary to wait 60 seconds.

7. Ensure that all DC connectors are securely in place.

8. In order to seal the inverter, all DC inputs that are

not required have to be closed as follows:
– Insert the sealing plugs provided into the

DC connectors that are not required.
Do not insert sealing plugs into the DC inputs
on the inverter.

– Insert the DC connectors with sealing plugs into

the corresponding DC inputs on the inverter.

The display is showing the
error message 40, 64 or
82.

• Follow the instructions on the display (see Section 11.2

"Error Messages", page 72).

Number of Strings - Sunny Tripower 10000TL / 12000TL
The Sunny Tripower models 10000TL / 12000TL only have four strings at input A.

Event

Measure