10 - 49

YASNAC PCNC Connecting Manual

Chapter 10: Connection of General Purpose I/O

When using an external (customer’s) power supply unit:

COM

10.2mA

RV

0

24

(a) For 0V common

.

.

Power Supply

0V

+24V

FIGURE 10.3.2.2 Input Circuit (when using an External Power Supply)

10.2 mA

COM

RV

0

24

(a) For 0V common

.

.

Power Supply

0V

+24V

FIGURE 10.3.2.3 Input Circuit (when using an External Power Supply)

POINT

In the input circuits (e.g. COM10,COM20,COM21,

____

9 in total), as shown in

“10.2 Detailed Connection of General-purpose I/O”, +24V common or 0V
common may be selected freely per 8 inputs or 16 inputs. For setting, use wire at