10 - 50

YASNAC PCNC Connecting Manual

Chapter 10: Connection of General Purpose I/O

(b) Output circuit (FC810/FC860)

Output uses non-contact polarity points. Limit the current at operation up to 60mA (per
circuit). For 24V power, either the power supply unit (JZNC-JAU07(option)) or the
external power supply may be used.

When using a power supply unit:

.

0

24

0

24

0

24

+24V CN7-1

CN7-2

24EX

Load

+ -

FIGURE 10.3.2.4 Output Circuit (when using a Power Supply Unit)

.

0

24

0

24

24EX

Load

+ -

Power Supply

+24V 0V

FIGURE 10.3.2.5 Output Circuit (when using a Power Supply Unit)