Yaskawa YASNAC PC NC Connecting Manual User Manual

Page 141

Advertising
background image

10 - 54

YASNAC PCNC Connecting Manual

Chapter 10: Connection of General Purpose I/O

(b) Output circuit

Output uses non-contact polarity points. Limit the current at operation up to 60mA
(per circuit). For 24V power, either power supply unit (JZNC-JAU07 (option)) or the
externalpower supply may be used.

When using a power supply unit

When using an external power supply unit

.

0

24

0

24

+24V

CNINT

Load

+ -

OV

FIGURE 10.3.2.9 Output Circuit (when using a Power Supply Unit)

.

0

24

0

24

+24V

CNEXT

Load
+ -

OV

.

Power Supply

+24V

OV

.

CN15-3

CN15-1

+24V

FIGURE 10.3.2.10 Output Circuit (when using a Power Supply Unit)

POINT

1.

56 output are non-contact polarity points (transistor, source driver), and limit the
current at ON up to 60mA (per circuit). When the load current of each output current
signal might exceed 60mA, install a fuse of 0.1A for each circuit in order to protect the
output IC.

2.

Up to 2.5A in the entire internal circuit (including JSP board) when using a power
supply unit.

Advertising