10 - 54
YASNAC PCNC Connecting Manual
Chapter 10: Connection of General Purpose I/O
(b) Output circuit
Output uses non-contact polarity points. Limit the current at operation up to 60mA
(per circuit). For 24V power, either power supply unit (JZNC-JAU07 (option)) or the
externalpower supply may be used.
•
When using a power supply unit
•
When using an external power supply unit
.
0
24
0
24
+24V
CNINT
Load
+ -
OV
FIGURE 10.3.2.9 Output Circuit (when using a Power Supply Unit)
.
0
24
0
24
+24V
CNEXT
Load
+ -
OV
.
Power Supply
+24V
OV
.
CN15-3
CN15-1
+24V
FIGURE 10.3.2.10 Output Circuit (when using a Power Supply Unit)
POINT
1.
56 output are non-contact polarity points (transistor, source driver), and limit the
current at ON up to 60mA (per circuit). When the load current of each output current
signal might exceed 60mA, install a fuse of 0.1A for each circuit in order to protect the
output IC.
2.
Up to 2.5A in the entire internal circuit (including JSP board) when using a power
supply unit.