8 - 3

YASNAC PCNC Connecting Manual

Chapter 8: Connection of Direct-IN/OUT Signals to the CNC

(b) For +24V common

(2) Connection of Direct OUT Signal

CN14-1

CN14-14

CN14-18

CN14-11 +24V

CN14-17

CN14-10 +24V

0V
COM

DIN1

DIN2

Direct IN 1

Direct IN 2

PCNC UNIT

FIGURE 8.2.1.2 Connection Details of Direct IN (for 24V Common)

CN14-20

CN14-1,2,3,9

JZNC-JFC10

.

.

DOUT

0V

Relay

FIGURE 8.2.1.3 Connection Details of Direct OUT