YASNAC PCNC Connecting Manual

Chapter 10: Connection of General Purpose I/O

(c) Output circuit (FC815)

Output uses non-contact polarity points. Limit the current at operation up to 60mA
(per circuit). For 24V power, both the power supply unit (JZNC-JAU07(option)) and
the external power supply may be used.

When using a power supply unit:

POINT

1.

96 outputs are non-contact polarity points (transistor, source driver), and limit the
current atON up to 60mA (per circuit). When the load current of each output signal
might exceed 60mA, install a fuse of 0.1A for each circuit in order to protect the output
IC.

2.

For 96 outputs, every 8 outputs may be connected to more than one external power
supply.

3.

Up to 2.5A in the entire internal circuit (including JSP board) when using a power
supply unit.

0

24

0

24

0

24

+24V

CN7-1

CN7-2

- +

Load

0

24

.

.

0

24EX

FIGURE 10.3.2.6 Output Circuit (when using a Power Supply Unit)