5 packaging, 1 general notes – Yaskawa YASNAC PC NC Connecting Manual User Manual

Page 32

Advertising
background image

1 - 14

YASNAC PCNC Connecting ManualChapter 1: General

1.5 Packaging

When designing the enclosure to house the CNC unit and other equipment, the construction
should provide for the following:

1.5.1

General Notes:

The enclosure must be air-tight.

Internal layout of components should provide for ease of mounting, inspection maintenance,

and removal.

There should be a physical gap of 100mm between components and the enclosure’s wall so

not to restrict air flow for cooling.

If the operation panel is built into the machine’s enclosure door, provisions to prevent vibra-

tion from the machine is necessary.

The average temperature increase in the enclosure should be limited to 10

o

C compared to the

external air.

Use a fan to circulate air to improve cooling efficiency within the enclosure. As a general rule,

the fan should blow air upward at 1m/s over the p.c. board’s surface.

The fan should not blow air directly onto the p.c.board.

To prevent malfunctions due to noises, keep noise generating elements 10m away from AC

power supply cables and components (over 90VDC).

When wiring, separate AC from DC lines, and separate primary side from the transformers’s

secondary side, line filter, etc.

Advertising