8 power supply unit for brake (opr109a,opr109f), Opr-109a, Single-phase – Yaskawa YASNAC PC NC Connecting Manual User Manual
Page 164: Half-wave, Opr-109f
Advertising
A1 - 15
YASNAC PCNC Connecting Manual
Appendix 1: Dimensions
1.8 Power Supply Unit for Brake (OPR109A,OPR109F)
Notes: 1. Do not short output terminals 3 and 4.
2. Tighten the terminal block screws securely.
3. An internal protection device is provided, so an external protection device is not
required.
4. The operating capacity of contacts used at “5” and “6” in the circuit diagram must be
5 to 10 times the brake’s current rating. Use the contact operating in DC.
Type
Rectifying
Method
Frequency
Hz
AC Input
Voltage
(AC) V
DC
Output
Voltage
(DC) V
DC Output
Current
A
Approximate
Mass
kg
OPR-109A
Single-phase
half-wave
50/60
200
90
1
0.1
OPR-109F
Single-phase
half-wave
50/60
100
90
1
0.1