8 power supply unit for brake (opr109a,opr109f), Opr-109a, Single-phase – Yaskawa YASNAC PC NC Connecting Manual User Manual

Page 164: Half-wave, Opr-109f

Advertising
background image

A1 - 15

YASNAC PCNC Connecting Manual

Appendix 1: Dimensions

1.8 Power Supply Unit for Brake (OPR109A,OPR109F)

Notes: 1. Do not short output terminals 3 and 4.

2. Tighten the terminal block screws securely.
3. An internal protection device is provided, so an external protection device is not
required.
4. The operating capacity of contacts used at “5” and “6” in the circuit diagram must be

5 to 10 times the brake’s current rating. Use the contact operating in DC.

Type

Rectifying

Method

Frequency

Hz

AC Input

Voltage

(AC) V

DC

Output

Voltage

(DC) V

DC Output

Current

A

Approximate

Mass

kg

OPR-109A

Single-phase

half-wave

50/60

200

90

1

0.1

OPR-109F

Single-phase

half-wave

50/60

100

90

1

0.1