7 Procedure B

34

YASKAWA TOEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Installation Manual

3.

Remove the lower terminal cover from the drive, if provided.
Apply pressure using fingers on the left and right tabs. Lift and pull the cover forward

to release.

IMPORTANT! The lower terminal cover is required for secure mounting of the

option on certain models. Use

Table 8

to find the lower terminal cover part number

by model. Contact your Yaskawa representative for ordering, if this part is not

available in your drive.

Table 8 Lower Terminal Cover Part Number by Model

Figure 27

Figure 27 Remove the Lower Terminal Cover

Drive Model CIMR-V

Terminal Cover Part Number

BA0006G/H and BA0010G/H
2A0010G/H and 2A0012G/H
4A0001G/H to 4A0009G/H

CVST31300

BA0012G/H
2A0020G/H
4A0011G/H

CVST31301

Other models

Not required