7 Procedure B

YASKAWA TOEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Installation Manual

39

12.

Attach the option unit to the drive by aligning the two mounting tabs on left and right
side of the option with slots on the drive. Plug-in the CN5 connector on the back of

the option unit into the CN5 connector on the drive. Tighten the screw in the front of

the option unit.

Figure 36

.

Figure 36

Figure 36 Attach Option Unit to Drive

13.

Insert the LED operator cable from the front cover into port CN1 on the drive.

Figure 37

Figure 37

Figure 37 Insert LED Operator Cable to Drive CN1 Port

CN5 Connector
port on drive

CN5 Connector

(underside of option)

Mounting Tab

Drive

CN1 Port

Inside front cover

Insert LED
operator cable