7 Procedure B

36

YASKAWA TOEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Installation Manual

6.

Select one of the four different length ground wires packaged with the option,

Figure 30

. Choose the proper ground wire by test fitting the screw (size M3.5 to M6)

into each of the four drive-side ground ring lugs prior to installation. Ground wire

selection varies by drive model.

Figure 30

Figure 30 Ground Wire Selection

7.

Connect the ground wire to the drive using the lower right screw that fastens the
drive to the case.

Tool tip: Use a long-shaft Phillips screwdriver. A magnetic tip screwdriver will aid in

keeping the screw captive during removal and installation.

Figure 31

Figure 31 Drive-side Ground Wire Connection

To Option ground screw FE
Screw size: M3

To drive ground terminal
Screw size: M3.5 to M6

Ground Wire

Lower-right screw

NEMA 4X Drive

Ground wire

Drive-side
ground terminal
Screw size:
M3.5 to M6

Option ground
screw FE
Screw size: M3

Long-shaft magnetic
tip screwdriver