Yaskawa GPD 515-G5 Modbus RTU User Manual

Page 46

Advertising
background image

7-10

Registers

Drive Parameter Registers (U2-XX / Fault Trace and U3-XX / Fault History) (continued)

REGISTER

PARAMETER

PARAMETER

PARAMETER

BIT

LIMITS / DESCRIPTION

(in hex)

FUNCTION

SETTING

NO.

08Ch

U2-13

Drive Status at Fault

0

Running at the time of fault

1

Zero-Speed at the time of fault

2

Reverse Running at the time of fault

3

Reset Signal Input at the time of fault

4

Speed Agree at the time of fault

5

Drive Operation Ready at the time of fault

6

Minor Fault

7

Major Fault

08Dh

U2-14

Elapsed Time at Fault

Elapsed Time at the time of fault (in hrs.)

090h

U3-01

Last Fault

Code of the most recent fault (1)

091h

U3-02

Fault Message 2

Code of the second to most recent fault (1)

092h

U3-03

Fault Message 3

Code of the third to most recent fault (1)

093h

U3-04

Fault Message 4

Code of the fourth to most recent fault (1)

094h

U3-05

Elapsed Time 1

Elapsed Time at the most recent fault occurrence

095h

U3-06

Elapsed Time 2

Elapsed Time at the second to most recent fault occurrence

096h

U3-07

Elapsed Time 3

Elapsed Time at the third to most recent fault occurrence

097h

U3-08

Elapsed Time 4

Elapsed Time at the fourth to most recent fault occurrence

Notes (for this page only):