7-22

Registers

Drive Parameter Registers (Read/Write) (continued)

REGISTER PARAMETER

PARAMETER

PARAMETER

LIMITS / DESCRIPTION

INITIAL

(in hex)

FUNCTION

SETTING

VALUE

415h

H4-01

Multi-function Analog Monitor 1

Selection (terminal 21)

1 to 31h

2

416h

H4-02

Multi-function Analog Monitor 1 Gain

0.00 to 2.50

1.00

417h

H4-03

Multi-function Analog Monitor 1 Bias

-10.0 to +10.0%

0.0

418h

H4-04

Multi-function Analog Monitor 2

Selection (terminal 23)

1 to 31h

3

419h

H4-05

Multi-function Analog Monitor 2 Gain

0.00 to 2.50

0.50

41Ah

H4-06

Multi-function Analog Monitor 2 Bias

-10.0 to +10.0%

0.0

41Bh

H4-07

Multi-function Analog Monitor Signal

0

0 to 10 V DC

0

Level Selection (terminal 21 & 23)

1

-10 to +10 V DC

41Ch

H5-01

Serial Communication Address

0 to 1Fh

1Fh

41Dh

H5-02

Serial Communication Baud Rate

0

1200 bps

1

2400 bps

3

2

4800 bps

3

9600 bps

41Eh

H5-03

Serial Communication

0

No Parity

Parity Selection

1

Even Parity

0

2

Odd Parity

41Fh

H5-04

Stopping Method after Serial

0

Ramp to Stop

Communication Error

1

Coast to Stop

3

2

Fast-Stop

3

Alarm Only

420h

H5-05

Communication Error (CE) Detection

0

Disabled

1

Selection

1

Enabled