Yaskawa GPD 515-G5 Modbus RTU User Manual

Page 54

Advertising
background image

7-18

Registers

Drive Parameter Registers (Read/Write) (continued)

REGISTER

PARAMETER

PARAMETER

PARAMETER

LIMITS / DESCRIPTION

INITIAL

(in hex)

FUNCTION

SETTING

VALUE

313h

E2-06

Motor Leakage Inductance

0.0 to 30.0%

(2)

314h

E2-07

Motor Iron-core Saturation Coefficient 1

0.00 to 0.50

0.50

315h

E2-08

Motor Iron-core Saturation Coefficient 2

0.00 to 0.75

0.75

316h

E2-09

Motor Mechanical Loss

0.0 to 10.0%

0.0

317h

E3-01

Motor 2 Control Method Selection

0

V/f Control

1

V/f with PG Feedback

2

2

Open Loop Vector

3

Flux Vector

318h

E4-01

Motor 2 Max. Output Frequency

50.0 to 400.0 Hz

7

319h

E4-02

Motor 2 Maximum Voltage

0.0 to 255.0V (230V unit)

0.0 to 510.0V (460V unint)

230.0
460.0

31Ah

E4-03

Motor 2 Max. Voltage Frequency

0.0 to 400.0 Hz

60.0

31Bh

E4-04

Motor 2 Mid. Output Frequency

0.0 to 400.0 Hz

(1)

31Ch

E4-05

Motor 2 Mid. Output Freq. Voltage

0.0 to 255.0V (230V unit)

0.0 to 510.0V (460V unint)

(1)

31Dh

E4-06

Motor 2 Min. Output Frequency

0.0 to 400.0 Hz

(1)

31Eh

E4-07

Motor 2 Min. Output Freq. Voltage

0.0 to 255.0V (230V unit)

0.0 to 510.0V (460V unint)

(1)

31Fh

E5-01

Motor 2 Rated Current

0.00 to 99.99 or 100.0 to 1500.0 Amps

(2)

320h

E5-02

Motor 2 Rated Slip

0.00 to 20.00 Hz

(2)

321h

E5-03

Motor 2 No-Load Current

0.00 to 99.99 or 100.0 to 1500.0 Amps

(2)

322h

E5-04

Motor 2 Number of Poles

2 to 48 poles

4

323h

E5-05

Motor w Line-to-Line Resistance

0.000 to 65.000 Ohms

(2)

324h

E5-06

Motor 2 Leakage Inductance

0.0 to 30.0%

(2)

Notes (for this page only):

1. Initial value differs depending on the Control Method (A1-02).
2. Initial value differs depending on drive capacity (o2-04).

Advertising