Page 100

4 Operation
4.1.1 Setting Switches S1, S2, and S3
4-4
(2) Settings of the DIP Switch S3
The following table shows the settings of the DIP switch (S3).
4.2 MECHATROLINK-III Commands
For information on the MECHATROLINK-III commands, refer to
Σ
-V Series User’s Manual MECHA-
TROLINK-III Standard Servo Profile Commands (SIEP S800000 63).
S3
Function
Setting
Factory
setting
Pins 1 and 2
Sets the number of
transmission bytes.
1
2
Number of transmission bytes
1: OFF
2: ON
OFF
OFF
16 byte
ON
OFF
32 byte
OFF
ON
48 byte
ON
ON
Reserved.
(Do not use this setting.)
Pin 3
Reserved. (Do not change.)
OFF
Pin 4
Reserved. (Do not change.)
OFF
• When using the MECHATROLINK-III standard servo profile, set the number of transmis-
sion bytes to either 32 or 48.
• When using the MECHATROLINK-II-compatible profile, set the number of transmission
bytes to either 16 or 32.
• Turn the power OFF and then ON again to enable the new settings.