5 servopack and converter internal block diagrams, 1 three-phase 200 v, M-iii – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual

Page 32

Advertising
background image

1 Outline

1.5.1 Three-phase 200 V

1-10

1.5 SERVOPACK and Converter Internal Block Diagrams

1.5.1 Three-phase 200 V

L1

+

B2

L2

U

V

W

- 1

L3

drive

MC

- 2

CHARGE

P24 V

SPD

P

N

+24 V

24C

+24 V

24C

CN103

CN104

CN901

P

N

CHARGE

ENC

M


CN103

CN104

P24 V

0 V

CN901

+24 V

˜6

24 V

+5 V

15 V

CN2

CN6A

CN6B

CN21

CN22

CN31

P24 V P24 V P24 V

-

B1

DU

DV

DW

CN115

CN5

CN3

CN7

CN8

CN1

I/O

Varistor

L1C

L2C


+5 V

+15 V

+24 V

˜2

24 V

24 V

Fan 1

Fan 2

Voltage

sensor

Control power supply

Main circuit

power supply

Voltage

sensor

Converter I/O

SERVOPACK
control power supply

Panel display

Feedback option

Safety option

MECHATROLINK

communications

(M-

III

)

Voltage sensor

gate drive

Temperature

sensor

Voltage

sensor

Temperature

sensor

Fan

2

Fan

1

Fan

4

Fan 3

(for 55-kW

models only)

Control

power

supply

ASIC

(PWM control, etc.)

CPU

(Position and speed

calculation, etc.)

PC

Digital

operator

Safety function

signals

Gate drive

Current

sensor

Dynamic

brake

unit

Analog

voltage

converter

Servomotor

I/O signals

Analog monitor output

Encoder pulse output

Regenerative
resistor unit

Control

power

supply

M-III

Advertising