9.2 Warning Displays

9-29

9

Trou

blesh

ooting

A.962
MECHATROLINK
Communications

Warning
(FCS Error)

MECHATROLINK

wiring is incorrect.

Confirm the wiring.

Correct the MECHATROLINK wir-
ing.

Or, connect a terminal to the terminal
station.

MECHATROLINK

data reception error
occurred due to noise
interference.

Confirm the installation conditions.

Take measures against noise. Check
the MECHATROLINK communica-
tions cable and FG wiring and take
measures such as adding ferrite core
on the MECHATROLINK communi-

cations cable.

A fault occurred in the
SERVOPACK.

A fault occurred in the SERVOPACK.
Replace the SERVOPACK.

A.963
MECHATROLINK
Communications

Warning
(Synchronization
Frame Not

Received)

MECHATROLINK
wiring is incorrect.

Confirm the wiring.

Correct the MECHATROLINK wir-
ing.
Or, connect a terminal to the terminal
station.

MECHATROLINK
data reception error
occurred due to noise

interference.

Confirm the installation conditions.

Take measures against noise. Check
the MECHATROLINK communica-
tions cable and FG wiring and take
measures such as adding ferrite core

on the MECHATROLINK communi-
cations cable.

A fault occurred in the

SERVOPACK.

A fault occurred in the SERVOPACK.
Replace the SERVOPACK.

A.971:
Undervoltage

The AC power supply
voltage dropped to:

• 140 V or less for 200-

VAC SERVOPACKs.

• 280 V or less for 400-

VAC SERVOPACKs.

Measure the power supply voltage.

Set the power supply voltage within
the specified range.

The power supply volt-
age dropped during
operation.

Measure the power supply voltage.

Increase the power supply capacity.

Occurrence of instanta-
neous power interrup-
tion.

Measure the power supply voltage.

When the instantaneous power cut
hold time (Pn509) is set, decrease the
setting.

A fault occurred in the
SERVOPACK or con-
verter.

The SERVOPACK or converter may
be faulty. Replace the SERVOPACK
or converter.

A.97A
Command

Warning 7
(Phase Error)

A command that cannot
be executed in the cur-
rent phase was sent.

Send a command after command
sending condition is satisfied.

A.97B
Data Clamp
(Out Of Range)

The set command data
was clamped to a mini-

mum or maximum
value out of the allow-
able setting range.

Set the value of the command data
within the allowable range.

(cont’d)

Warning Num-

ber: Warning

Name (Warning

Description)

Cause

Investigative Actions

Corrective Actions