9.2.1 List of Warnings

This section provides list of warnings.

Warning

Number

Warning Name

Meaning

Reset

A.900

*1

Position Error Overflow

Position error exceeded the parameter setting (Pn520

×Pn51E/100).

Required

A.901

*1

Position Error Overflow

Alarm at Servo ON

When the servomotor power is ON, the position error exceeded the parameter
setting (Pn526

×Pn528/100).

Required

A.910

*1

Overload

This warning occurs before the overload alarms (A.710 or A.720) occur. If the
warning is ignored and operation continues, an overload alarm may occur.

Required

A.911

*1

Vibration

Abnormal vibration at the motor speed was detected. The detection level is the
same as A.520. Set whether to output an alarm or warning by the vibration
detection switch (Pn310).

Required

A.920

*1

Regenerative Overload

This warning occurs before the regenerative overload alarm (A.320) occurs. If
the warning is ignored and operation continues, a regenerative overload alarm
may occur.

Required

A.921

*1

Dynamic Brake Overload

This warning occurs before dynamic brake overload alarm (A.731) occurs. If
the warning is ignored and operation continues, a dynamic brake overload
alarm may occur.

Required

A.930

*1

Absolute Encoder Battery

Error

This warning occurs when the voltage of absolute encoder’s battery is lowered. Required

A.94A

*2

Data Setting Warning 1

(Parameter Number Error) Incorrect command parameter number was set.

Automatic
reset

*4

A.94B

*2

Data Setting Warning 2

(Out of Range)

Command input data is out of range.

Automatic
reset

*4

A.94C

*2

Data Setting Warning 3

(Calculation Error)

Calculation error was detected.

Automatic
reset

*4

A.94D

*2

Data Setting Warning 4

(Parameter Size)

Data size does not match.

Automatic
reset

*4

A.94E

*2

Data Setting Warning 5

(Latch Mode Error)

Latch mode error is detected.

Required

A.95A

*2

Command Warning 1

(Unsatisfying Command)

Command was sent although the conditions for sending a command were not
satisfied.

Automatic
reset

*4

A.95B

*2

Command Warning 2

(Non-supported

Command)

Unsupported command was sent.

Automatic
reset

*4

A.95D

*2

Command Warning 4

(Command Interference)

Command, especially latch command, interferes.

Automatic
reset

*4

A.95E

*2

Command Warning 5

(Subcommand Disable)

Subcommand and main command interfere.

Automatic
reset

*4

A.95F

*2

Command Warning 6

(Undefined Command)

Undefined command was sent.

Automatic
reset

*4

A.960

*2

MECHATROLINK
Communications Warning

Communications error occurred during MECHATROLINK communications.

Required

A.962

*2

MECHATROLINK

Communications Warning

(FCS Error)

Communications error occurred during MECHATROLINK communications.

Required