5.6 Anti-Resonance Control Adjustment Function (Fn204)

5-51

5

Adjustm

e

nts

5.6.3 Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-

cuting this function or of being changed automatically after executing this function.

• Parameters related to this function

These are parameters that are used or referenced when executing this function.

• Allowed changes during execution of this function

Yes : Parameters can be changed using SigmaWin+ while this function is being executed.

No : Parameters cannot be changed using SigmaWin+ while this function is being executed.

• Automatic changes after execution of this function

Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.

Parameter

Name

Mid-execution

changes

Automatic

changes

Pn160

Anti-Resonance Control Related Switch

Yes

Yes

Pn161

Anti-Resonance Frequency

No

Yes

Pn162

Anti-Resonance Gain Compensation

Yes

No

Pn163

Anti-Resonance Damping Gain

No

Yes

Pn164

Anti-Resonance Filter Time Constant 1 Compensation

Yes

No

Pn165

Anti-Resonance Filter Time Constant 2 Compensation

Yes

No