Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual

Page 388

Advertising
background image

10.1 List of Parameters

10-39

10

Ap

pend

ix

41
PnA82

4

Speed Unit

*2

0 to 4

0

After

restart

Unit System

Related

Parameters

0000H

reference unit/sec

0001H

reference unit/min

0002H

Percentage (%) of rated speed

*3

0003H

min

-1*3

0004H

Max. motor speed/40000000H

*4

42

PnA84

4

Speed Base Unit

(Set the value of “n” used as the
exponent in 10

n

when calculating

the Speed Unit (41).)

*3*4

-3 to 3

0

After

restart

43

PnA86

4

Position Unit

0

0

After

restart

0000H

reference unit

44

PnA88

4

Position Base Unit

(Set the value of “n” used as the
exponent in 10

n

when calculating

the Position Unit (43).)

0

0

After

restart

45

PnA8A

4

Acceleration Unit

0

After

restart

0000H

reference unit/sec

2

0001H

Not supported

∗2. When using fully-closed loop control, set 0000H (Reference unit/sec).

∗3. When either 0002H or 0003H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42)

to a number between -3 and 0.

∗4. When 0004H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to 0.
Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or

the power must be turned OFF and then ON again.

(cont’d)

Parameter

No.

Size

Name

Setting Range

Units

[Resolution]

Factory

Setting

When

Enabled

Classifica-

tion

Advertising