10 Appendix

10.1.3 MECHATROLINK-III Common Parameters

10-44

8A

PnB14

4

Monitor Selection for SEL_MON2
(CMN2)

0 to 6

0

Immedi-

ately

Command

Related

Parameters

0000H
to

0006H

Same as Monitor Selection for SEL_MON1.

8B

PnB16

4

Origin Detection Range

0 to 250

1 reference unit

10

Immedi-

ately

8C

PnB18

4

Forward Torque Limit

0 to 800

1%

100

Immedi-

ately

8D

PnB1A

4

Reverse Torque Limit

0 to 800

1%

100

Immedi-

ately

8E

PnB1C

4

Zero Speed Detection Range

1000 to

10000000

10

-3

min

-1

20000

Immedi-

ately

8F

PnB1E

4

Speed Coincidence Signal Output
Width (read only)

0 to 100000

10

-3

min

-1

10000

Immedi-

ately

90

PnB20

4

Servo Command Control Field
Enabled/Disabled (read only)

0FFF3F3FH

Bit 0

CMD_PAUSE (1: Enabled)

Bit 1

CMD_CANCEL (1: Enabled)

Bit 2, 3

STOP_MODE (1: Enabled)

Bit 4, 5

ACCFIL (1: Enabled)

Bit 6, 7

Reserved (0: Disabled)

Bit 8

LT_REQ1 (1: Enabled)

Bit 9

LT_REQ2 (1: Enabled)

Bit 10,
11

LT_SEL1 (1: Enabled)

Bit 12,

13

LT_SEL2 (1: Enabled)

Bit 14,
15

Reserved (0: Disabled)

Bit 16 to
19

SEL_MON1 (1: Enabled)

Bit 20 to
23

SEL_MON2 (1: Enabled)

Bit 24 to
27

SEL_MON3 (1: Enabled)

Bit 28 to
31

Reserved (0: Disabled)

Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or

the power must be turned OFF and then ON again.

(cont’d)

Parameter

No.

Size

Name

Setting Range

Units

[Resolution]

Factory

Setting

When

Enabled

Classifica-

tion

Advertising