Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual
Page 299
Advertising

8.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
8-11
8
Fu
lly-close
d L
oop
Co
ntro
l
• Setting of Pn081.0
Do not change the factory setting if the zero point position of the existing equipment
must remain as is.
• When Pn081.0 = 1, the width of the phase-C pulse output is narrower than that of
the phase-A pulse in some cases.
• As shown in the following figure, there is a one-eighth scale pitch difference in posi-
tions between the two settings (Pn081.0 = 1 and Pn081.0 = 0) for the phase-C
pulse output, the zero point return command, and the phase-C detection by phase-
C latch function.
1/8
scale pitch
Pn081.0 =
0
Zero point
Zero point
Moves to forward
1 scale pitch
Pn081.0 =
1