You can exit the fluid change service at any phase of the

operation with N button.

9) To complete the second phase of operation, do the following as

instructed:
- Turn off filling and bleeding equipment.
- Wait until the pressure drops.
- Disconnect filling and bleeding equipment.

10) Press Y button to move to next phase.
11) To complete the third phase, do the following as instructed:

- Set pressure: 0.5bar.
- Wait until the pressure has built up.

12) Press Y button to move to phase 4.
13) Following instructions on device screen to finish the fourth phase:

- Reduce pressure at filling and bleeding unit to 0bar.
- Turn off filling and bleeding equipment.
- Leave filling and bleeding unit connected.
- Wait until the pressure drops.
- If the filling and bleeding unit has a shutoff valve, close it.
- Switch on filling and bleeding unit.

14) Press Y button to continue with phase 5.
15) Follow onscreen instructions to finish the fifth phase.

- Set pressure: 2.0→2.5 bar.
- If present, open shutoff valve for filling and bleeding unit.
- Wait until the pressure has built up.
- Hold bleeder hose tight.
- The pressure at the bleeder screw is greater than 100bar!

16) Press Y button to continue.
17) Follow onscreen instructions to finish the sixth phase.

- Close bleeder screw at rear right brake calliper.
- Open bleeder screw at rear left brake calliper.
- Hold bleeder hose tight.

18) Press Y button to continue.
19) Follow onscreen instructions to finish the seventh phase.

- Close bleeder screw at rear left brake calliper.
- Open bleeder screw at front left brake calliper.
- Operate brake pedal at least 5 times and release again (pump).
- Stop pumping once the brake fluid flows out free of bubbles.
- Hold bleeder hose tight.