28) Actuate the pedal gently to raise the pressure to 20-24 bar and

keep it for 5s.

29) Follow onscreen instructions to complete operation of current

phase:
- The fill level of wheel brake circuit HZ1 (primary brake circuit)
is in order.
- Release brake pedal.
- Brake system fill status is OK.

30) Press Y button or gently actuate and then release the pedal to

complete the air inspection service and following screen shows:

........

Inspect Brake Air

.... .

1. The test is OK.

2. No air is in brake

system.

3. End of test.

If the device fails to inspect brake air, following screens

come up:

prompt screen to be continued…

........

Inspect Brake Air

.... .

1. Fail to inspect

brake system for

air.

2. Function of SBC is

not assured.

........

Inspect Brake Air

.... .

3. Please repeat the

process.

31) Press any key to return.


VS8622_1.03_12/03/09

32