20 ma analog inputs, Flow meter pulse inputs, Digital inputs – Precision Digital PD941 User Manual

Page 8

Advertising
background image

ConsoliDator Multi-Channel Controller

Instruction Manual

8

4-20 mA Analog Inputs

INPUT

4-20 mA; minimum span of 1 mA

ACCURACY

±0.03% of span

1 count

TEMPERATURE DRIFT

50 PPM/

C from 0 to 50°C ambient

INPUT FUNCTION

Linear, Square Root, Programmable Exponent, Multi-Point
(up to 32), or Fixed Value

MATH FUNCTION

Sum or difference of 2 or more channels.

TOTALIZER

Calculates total based on rate and time base of second,
minute, hour, or day; stored in non-volatile memory every 5
minutes; supports linear inputs only.

TOTALIZER RESET

Via front panel buttons (password restricted)

DECIMAL POINT

User selectable zero to six places with automatic overflow.

INPUT RANGE

4-20 mA, Minimum span of 1 mA

INPUT IMPEDANCE

130

NORMAL MODE
REJECTION

Greater than 100 dB at 50/60 Hz.

TRANSMITTER POWER
SUPPLY

Each input is equipped with +24 VDC current limited to
40 mA. External supply may be substituted.

ENGINEERING UNITS

User selectable units or custom-entered units.

Flow Meter Pulse Inputs

ACCURACY

±1 count for K-Factor > 1

SIGNAL RANGE

100 mVp-p to 15 Vp-p; 1 Hz to 10 kHz

K-FACTOR

Programmable from 0.00001 to 999999 pulses/unit

DISPLAY OPTIONS

Rate and total values displayed on screen.
Bargraphs user selectable to indicate either total or rate.

ENGINEERING UNITS

Show Total/Rate combinations:
GAL & GPS, GAL & GPM, GAL & GPH, GAL & GPD, MG &
MGD, BBL & BPH, BBL & BPD, LTR & LPs, LTR & LPM,
LTR & LPH, LTR & LPD, CF & CFS, CF & CFM, CF &
CFH, CF & CFD, MCF & MCD.

RATE & TOTAL
DECIMAL POINT

Independent and user selectable from zero to six places
with automatic overflow.

TOTALIZER

Calculates total based on rate. Reading stored in non-
volatile memory every 5 minutes for power-loss recovery.

TOTALIZER RESET

Via front panel buttons (Password restricted)

Digital Inputs

INPUT TYPES

Normally open switch: External excitation not required.
Open collector transistor: Open circuit voltage = 3 VDC
Closed Circuit Current = 18.5 mA
Switch closure or logic LO to terminals interpreted as "ON"
LO = 0 to 1 VDC, HI = 2.5 to 12 VDC

INPUT IMPEDANCE

240

SIGNAL REQUIREMENTS

Minimum input pulse (closed contact or LO) duration: 1 sec
Maximum input pulse frequency: 30 cycles per minute